Ultrasonic diagnosis instrument for liver

Hepatus 6

Intelligent and efficient

Ushering in a new era of noninvasive liver disease diagnosis
Hepatus 6 Liver ultrasonic diagnostic instrument
Liver health can't be ignored. However, because the liver has no pain nerve, the performance of chronic liver disease is extremely hidden, becoming a "silent killer". If left unattended, fatty liver, liver fibrosis will further progress to cirrhosis, and even liver cancer and liver failure. Hepatus 6 is a specialized liver diagnosis system for the noninvasive quantitative measurement of liver fibrosis and steatosis. It is non-invasive and painless, reliable quantitative, sensitive and accurate, and convenient for disease tracking, and is the first choice for chronic liver disease examination. It is unique, intelligent and efficient, and opens a new era of non-invasive liver disease diagnosis.
Quantitative analysis of liver hardness
The degree of liver fibrosis was evaluated quantitatively by the instantaneous elastic technique
zhg963-s2-1
Quantitative analysis of hepatic adipose change
The degree of hepatic steatosis was quantitatively assessed by detecting ultrasonic attenuation
zhg963-s2-2

Wide clinical application

It is suitable for screening, diagnosis, monitoring, treatment and evaluation of liver fibrosis and steatosis caused by various causes, and is conducive to early screening, early diagnosis, early treatment and early rehabilitation of various chronic liver diseases.

  • Nonalcoholic fatty liver
  • Alcoholic liver disease
  • Chronic hepatitis B
  • Chronic hepatitis C
  • Drug-induced liver injury
  • Autoimmune liver disease
  • Biliary tract disease
zhg963-s3
Transient elastography is recommended for chronic liver disease
hepatus-series-fig4-1
Non-invasive and painless
Avoid liver biopsy, reduce the risk of biopsy, simple and rapid examination, suitable for all kinds of people, non-invasive and painless, safe and economic.
hepatus-series-fig4-2
Quantitative and reliable
The technique for quantitative detection and evaluation of liver fibrosis and steatosis has been widely recommended by global liver guidelines, and the diagnostic criteria are mature and reliable.
hepatus-series-fig4-3
Sensitive and accurate
High sensitivity to liver fibrosis and fatty degeneration, high detection accuracy, which is conducive to early screening, early diagnosis, early treatment and early rehabilitation of liver diseases.
hepatus-series-fig4-4
Disease tracking
The reproducibility of the test allows doctors to monitor the results of the same patient at different times for disease tracking and treatment evaluation.

Unique insight, accurate detection

Mindray's innovative ViTE visualization instantaneous elasticity
Visual Transient Elastography
  • The quantitative evaluation of liver fibrosis and liver steatosis was performed under the visual guidance of real-time 2D ultrasound
  • Ensures accurate and reliable positioning, avoiding blood vessels and lesions
  • Greatly reduce the difficulty of operation, improve the success rate, accuracy and repeatability of quantitative detection
zhg963-s5

Get to the bottom of it and rest easy

All-in-one probe
  • Ultra-wideband frequency conversion technology, a single probe covers all populations, and patients of different body types/ages do not need to switch probes
  • Multi-array oscillator, single probe synchronous two-dimensional guidance and quantitative detection, no need to change the probe
  • Key integration, the collection process is completed with one key
zhg963-s6

Smart, fast and easy

Mindray features Q-Scan intelligent acquisition
  • One key automatic continuous collection and intelligent screening of 10 groups of effective data
  • Only 7 seconds after positioning, accurate and effective detection results, waiting is preferable
  • The inspection time is greatly shortened, and the detection efficiency is doubled
zhg963-s7

Double ring quality control, Yan and letter

Double ring quality control
  • Probe pressure ring (P) : quality control probe pressure
  • Motor Stability ring (M-STB) : Respiratory stability of quality control patients
  • The yellow light indicates that the green light is up to standard, and the color indication is intuitive
  • Strict quality control, testing double insurance, the result is trustworthy
zhg963-s8

Trend analysis, disease tracking

Intelligent trend analysis
  • Check the same patient at different times, automatically retrieve and statistical test reports and data, and analyze the trend
  • It is convenient for doctors to monitor the changes of patients' liver status, which is conducive to disease tracking and treatment effect evaluation
  • Test data can be exported, which is convenient for doctors to study and analyze
zhg963-s9

Color ultrasound complements the diagnosis

Color ultrasound expansion
  • Expand the probe to check for ascites, etc
  • Professional ultrasound guided puncture, improve the accuracy of biopsy
  • Excellent abdominal color ultrasound imaging and function, comprehensive assessment of liver morphology and hemodynamics, assist clinical diagnosis
zhg963-s10
Human design, experience outstanding

Adopt innovative ergonomic design to bring intuitive, convenient and intelligent user experience.